MEASURING DATA ACQUISITION HARDWARE FOR ELECTRICAL IMPEDANCE TOMOGRAPHY

cris.lastimport.scopus2024-09-18T01:30:42Z
dc.abstract.enThis article presents the design of the device with active electrodes to examine the flood embankment. There was discussed the method of determining the conductivity. The presented solution was based on electrical impedance tomography. There was described the concept of active electrodes and measuring equipment for data acquisition. Electrical impedance tomography, which is based on measuring potential difference, can be used to calculate conductivity. The problem depends on the fact that every material has unique conductance.
dc.affiliationTransportu i Informatyki
dc.contributor.authorTomasz Rymarczyk
dc.contributor.authorKarol Duda
dc.contributor.authorPaweł Rymarczyk
dc.contributor.authorDaniel Olchowy
dc.contributor.authorJan Sikora
dc.date.accessioned2024-05-09T08:47:23Z
dc.date.available2024-05-09T08:47:23Z
dc.date.issued2017
dc.identifier.doi10.5604/01.3001.0010.4591
dc.identifier.issn2083-0157
dc.identifier.issn2391-6761
dc.identifier.urihttps://repo.akademiawsei.eu/handle/item/293
dc.languageen
dc.pbn.affiliationinformation and communication technology
dc.relation.ispartofInformatics Control Measurement in Economy and Environment Protection
dc.rightsCC-BY-SA
dc.subject.enElectrical Impedance Tomography
dc.subject.enActive Electrodes
dc.subject.enFlood Embankment
dc.titleMEASURING DATA ACQUISITION HARDWARE FOR ELECTRICAL IMPEDANCE TOMOGRAPHY
dc.typeReviewArticle
dspace.entity.typePublication
oaire.citation.issue1
oaire.citation.volume7